CAD Drawings nVent Thermal Management Fire Rated Wiring System
CAD Drawings nVent Thermal Management Fire Rated Wiring System

Protect Critical Circuits in Case of Fire

  • Worldwide regulations require fire protection for emergency feeder circuits in commercial buildings, public spaces, hospitals, industrial plants and refineries. Critical equipment and processes must continue to operate during an emergency to minimize damage and protect lives. 
  • Setting the Standard in Fire Safety 
  • Historically, fire safety of critical circuits was achieved by running conventional cables behind a heat barrier such as a gypsum board or hollow concrete block; or by embedding the conductors in concrete. nVent PYROTENAX mineral insulated fire-rated cables are UL listed and can withstand temperatures up to 1850°F (1010°C) for two hours. This built-in fire resistance provides greater protection as opposed to the fire-rating of conventional cables which require heat barrier systems.

Pre-assembled Collections CLICK ON THE LISTING BELOW TO DOWNLOAD FILES Back To Top

CAD
3D
Specs
About
Media
Education
PrintCAD
Close
1
nVent PYROTENAX System 1850 Cable
Close
2
Typical Trapeze Support Installation Detail
Close
3
Typical Alternate Trapeze Support Installation Detail
Close
4
MI Cable Steel Strut Framing System Support Detail
Close
5
MI Cable Banding Bracket System Detail
Close
6
MI Cable Clips and Straps Detail
Close
7
Typical System 1850 Fire-Rated Circuit Detail
Close
8
MI Surface Installation Detail
Close
9
System 1850 2-Hour Fire-Rated Cable Specification (US)
Close
10
System 1850 2-Hour Fire-Rated Cable Specification (CAN)
Close
11
nVent PYROTENAX MI Tools
Close
12
nVent PYROTENAX MI Accessories
Close
13
nVent PYROTENAX MI Terminations
Close
14
nVent PYROTENAX MI Splices
Close
15
Typical Service Entrance Installation With Tray Mounted On Steel Trapeze
Close
16
Typical Service Entrance Installation With Steel Trapeze Mounted Inside Cable Tray

All Available 2D CAD Files Back To Top

CAD Drawings nVent Thermal Management Typical Trapeze Support Installation Detail
Typical Trapeze Support Installation...
View CAD
CAD Drawings nVent Thermal Management Typical Alternate Trapeze Support Installation Detail
Typical Alternate Trapeze Support...
View CAD
CAD Drawings nVent Thermal Management MI Cable Steel Strut Framing System Support Detail
MI Cable Steel Strut Framing System...
View CAD
CAD Drawings nVent Thermal Management MI Cable Banding Bracket System Detail
MI Cable Banding Bracket System Detail
View CAD
CAD Drawings nVent Thermal Management MI Cable Clips and Straps Detail
MI Cable Clips and Straps Detail
View CAD
CAD Drawings nVent Thermal Management Typical System 1850 Fire-Rated Circuit Detail
Typical System 1850 Fire-Rated Circuit...
View CAD
CAD Drawings nVent Thermal Management MI Surface Installation Detail
MI Surface Installation Detail
View CAD
CAD Drawings nVent Thermal Management Typical Service Entrance Installation With Tray Mounted On Steel Trapeze
Typical Service Entrance Installation...
View CAD
CAD Drawings nVent Thermal Management Typical Service Entrance Installation With Steel Trapeze Mounted Inside Cable Tray
Typical Service Entrance Installation...
View CAD

All Available Specifications Back To Top

System 1850 2-Hour Fire-Rated Cable...
View Spec
System 1850 2-Hour Fire-Rated Cable...
View Spec
©2019 CADdetails.com Ltd. All rights reserved